Lately, I have been receiving X10 errors, usually after my nightly PC restart. I am running HS2 (TI103) & HS3 (CM11a) on the same Win 8.1 PC. The machine is restarted, because HS2 becomes unstable if I don't, every evening late and HS3 is then re-started via Task Scheduler about 2 or 3 minutes after HS2. Here is what the log looks like:
4/14/2016 11:59:29 PM,Startup,HomeSeer version is: 3.0.0.280
4/14/2016 11:59:30 PM,Plug-In,Found plug-in: X10, version: 3.0.0.36
4/14/2016 11:59:31 PM,Plug-In,Finished initializing plug-in X10
Then, from a repeating script I issue 4 CAPI X10 commands:
4/14/2016 11:59:40 PM,Device Control,Device: First Floor Office Test Light to Off (0) by/from: CAPI Control Handler
4/14/2016 11:59:40 PM,Device Control,Device: First Floor Foyer Night-Light to On (100) by/from: CAPI Control Handler
4/14/2016 11:59:40 PM,Device Control,Device: First Floor Kitchen Light-Cabinet-OH to Off (0) by/from: CAPI Control Handler
4/14/2016 11:59:40 PM,Device Control,Device: First Floor Front Porch Light-Porch-Switch to On (100) by/from: CAPI Control Handler
And immediately receive these 4 errors:
4/14/2016 11:59:40 PM,X10 ERROR,error in ControlDevice :Object variable or With block variable not set.
4/14/2016 11:59:40 PM,X10 ERROR,error in ControlDevice :Object variable or With block variable not set.
4/14/2016 11:59:40 PM,X10 ERROR,error in ControlDevice :Object variable or With block variable not set.
4/14/2016 11:59:40 PM,X10 ERROR,error in ControlDevice :Object variable or With block variable not set.
This error repeats for every X10 command issued, and they all fail. I can usually manually restart HS3 and all is fine.
Guidance would be appreciated on possible causes and/or how to further debug this error.
Thanks
Gary
4/14/2016 11:59:29 PM,Startup,HomeSeer version is: 3.0.0.280
4/14/2016 11:59:30 PM,Plug-In,Found plug-in: X10, version: 3.0.0.36
4/14/2016 11:59:31 PM,Plug-In,Finished initializing plug-in X10
Then, from a repeating script I issue 4 CAPI X10 commands:
4/14/2016 11:59:40 PM,Device Control,Device: First Floor Office Test Light to Off (0) by/from: CAPI Control Handler
4/14/2016 11:59:40 PM,Device Control,Device: First Floor Foyer Night-Light to On (100) by/from: CAPI Control Handler
4/14/2016 11:59:40 PM,Device Control,Device: First Floor Kitchen Light-Cabinet-OH to Off (0) by/from: CAPI Control Handler
4/14/2016 11:59:40 PM,Device Control,Device: First Floor Front Porch Light-Porch-Switch to On (100) by/from: CAPI Control Handler
And immediately receive these 4 errors:
4/14/2016 11:59:40 PM,X10 ERROR,error in ControlDevice :Object variable or With block variable not set.
4/14/2016 11:59:40 PM,X10 ERROR,error in ControlDevice :Object variable or With block variable not set.
4/14/2016 11:59:40 PM,X10 ERROR,error in ControlDevice :Object variable or With block variable not set.
4/14/2016 11:59:40 PM,X10 ERROR,error in ControlDevice :Object variable or With block variable not set.
This error repeats for every X10 command issued, and they all fail. I can usually manually restart HS3 and all is fine.
Guidance would be appreciated on possible causes and/or how to further debug this error.
Thanks
Gary